MAGNETOTELLURICS

What is the MT / AMT method?

Magnetotellurics (MT) is a passive electromagnetic method that uses natural variations of the Earth’s electric and magnetic fields. At each station the electric field (Ex, Ey) is measured with non-polarisable electrode dipoles and the magnetic field (Hx, Hy, Hz) with induction coil magnetometers; their ratio, the impedance, gives apparent resistivity and phase as a function of frequency.

Because lower frequencies penetrate deeper (skin depth), MT can, depending on ground conditions, image resistivity from hundreds of metres to several kilometres. AMT uses the higher, audio-frequency band for shallower and more detailed investigation. This makes the methods suitable for deep mineral and geothermal exploration, where active-source methods reach their depth limits.

MT station layout: two orthogonal electric dipoles, three induction coils and the recording unitADUExEyHxHyHz
Typical MT station layout (schematic)

01 / APPLICATIONS

Where MT / AMT is used

  • Geothermal exploration: conductive clay cap, reservoir, fault zones and heat-source structure
  • Deep mineral exploration: porphyry and sulphide systems, alteration zones, conductive bodies and structural controls
  • Basin structure and depth to basement
  • Regional faults and crustal structure
  • Deep groundwater and hydrogeological structure
  • Complementing TEM, ERT and gravity data at depth

02 / PRINCIPLE

Frequency and depth

The natural field has different sources across the spectrum: at low frequencies mainly interactions of the solar wind with the magnetosphere and ionosphere, and at higher frequencies worldwide lightning activity. The depth an electromagnetic wave reaches increases as frequency decreases and as ground resistivity increases.

AMT typically uses the audio band (roughly 1 Hz to 10 kHz) for shallow to intermediate depths with higher resolution; MT records lower frequencies over longer periods to reach kilometre-scale depths. Where the natural signal is weak or cultural noise is high, controlled-source AMT (CSAMT) with a transmitter can be used.

For shallower targets, TEM and ERT give higher resolution; MT / AMT extends the resistivity picture to depths these methods cannot reach. Combined with gravity and magnetic data, it supports structural interpretation.

03 / EQUIPMENT AND SOFTWARE

Equipment and Software

SAGTECH uses the following instruments and software in MT/AMT surveys.

Metronix ADU-07e

24-bit geophysical EM data acquisition system and the core unit of the GMS-07 system. DC–250 kHz frequency range, 1 to 10 channels, LF/MF/HF bands and a dynamic range above 130 dB. GPS time synchronisation allows networked multi-station recording over LAN/WLAN; rugged design for −40 °C to +60 °C. Supports MT, AMT and CSAMT.

Metronix MFS-06e

Broadband induction coil magnetometer for MT and CSAMT, covering 0.0001 Hz to 10 kHz with very low noise (about 1.1×10⁻⁴ nT/√Hz at 1 Hz). Length 1140 mm, about 8 kg.

Electric field dipoles

Orthogonal dipoles with non-polarisable electrodes record the horizontal electric field components (Ex, Ey).

ModEM 3D inversion

Modular, parallel 3D inversion code for MT and CSEM developed at Oregon State University (KMS Technologies / ModEM Geophysics). Uses EDI data, allows geological constraints and static-shift handling, and produces 3D resistivity models with data-fit assessment.

04 / OUTPUTS

What the survey provides

  • Apparent resistivity and phase curves for each station
  • Data quality and dimensionality analysis
  • 1D and 2D resistivity models along profiles
  • 3D resistivity models and depth slices
  • Interpretation integrated with geology, drilling and other geophysical data

05 / WORKFLOW

How a survey is carried out

  1. Planning

    Target depth, station spacing, frequency bands and recording times are defined from the geology and the project objective.

  2. Field set-up

    Electric dipoles and induction coils are laid out at each station; positions are recorded with GPS.

  3. Recording

    Time series are recorded for the required duration; a remote reference station can be used to reduce noise.

  4. Processing

    Time series are processed into impedance, apparent resistivity and phase.

  5. Quality control and modelling

    Data quality and dimensionality are checked; data are modelled in 1D, 2D or 3D and interpreted with geology to support drilling decisions.

  6. Reporting

    Sections, models and the interpretation are delivered in a technical report.

06 / COST

What determines the cost

  • Number of stations and station spacing
  • Target depth and required frequency range
  • Recording time per station
  • Electrical noise at the site
  • 2D or 3D modelling
  • Site access and terrain

Request an MT / AMT survey quote

FAQ

MT / AMT questions

What is the MT method?

Magnetotellurics (MT) is a passive electromagnetic method that records natural variations of the Earth’s electric and magnetic fields at the surface. The ratio of these fields gives the resistivity of the subsurface as a function of frequency and therefore depth.

What is the difference between AMT and MT?

AMT (audio-magnetotellurics) uses the higher frequency band and examines shallower to intermediate depths with higher resolution. MT also records much lower frequencies and longer periods, so it can reach several kilometres and deeper. The two are often combined.

How deep can MT investigate?

Investigation depth depends on the recorded frequency range and the resistivity of the ground: lower frequencies and more resistive ground give greater depth. AMT typically covers shallow to intermediate depths, while long-period MT can reach the deep crust.

Why is MT used in geothermal exploration?

Geothermal systems often contain conductive clay alteration above the reservoir and fault zones that carry fluids. MT maps these resistivity contrasts to depths that other electrical methods cannot reach, helping to plan exploration wells.

What does MT / AMT provide in mineral exploration?

It images conductive bodies, alteration zones and the faults and structures that control mineralisation as resistivity models at depths shallow methods cannot reach. Combined with geology and other geophysical data, the results help define drilling targets.

Does electrical noise affect MT measurements?

Yes. Power lines, pipelines, electric railways and other sources can disturb the natural signal. Station locations are planned away from known noise sources, and remote-reference processing can reduce noise; controlled-source CSAMT can be used where needed.